Abstract

Impedance pneumography (IP) system for breathing pattern monitoring was developed. IP system was calibrated volumetrically using integrated pneumotachigraphy. We studied mean breathing pattern parameters in 39 healthy subjects, patients with mild (n=39), moderate (n=25) and severe (n=17) bronchial asthma (BA) in sitting posture during 10 min. interval. Mean breathing rate was significantly (p<0.05) higher in all BA groups (18.0±0.6, 18.0±0.6, 20.4±1.2 /min., M±m) than in controls (16,2±0,6 /min.). Patients with severe BA demonstrated significantly higher mean partial expiratory time (58.2±0.8%) and lower mean tidal volume (0.35±0.04 I) than healthy subjects (55.8±0.5% and 0.47±0.02 I, respectively). We concluded that developed noninvasive breathing pattern monitoring method is informative in patients with BA.

About the Authors

R. Kh. Zoulkarneev
Башкирский государственный медицинский университет
Russian Federation


Sh. Z. Zagidullin
Башкирский государственный медицинский университет
Russian Federation


S. A. Kolikova
Башкирский государственный медицинский университет
Russian Federation


L. M. Kajumova
Башкирский государственный медицинский университет
Russian Federation


References

1. Бреслав И.С. Паттерны дыхания: физиология, экстремальные состояния, патология. Л.: Наука; 1984.

2. Всемирная организация здравоохранения. Национальный институт здоровья США. "Бронхиальная астма. Глобальная стратегия." Пульмонология 1996; Прил.: 1-165.

3. Дьяченко А.И. Влияние положения тела человека на дыхательный импеданс. Физиология человека 1996; 22 (1): 104-110.

4. Ярмолинский В.И. Выбор оптимальных условий количественной импедансной пневмографии. В кн.: Измерения в медицине и их метрологическое обеспечение. М.; 1986.

5. Askanazi J., Silverberg P.A., Foster R.J. Effects of respiratory apparatus on breathing pattern. J. Appl. Physiol. 1980; 48: 577.

6. Kuratomi Y., Okazaki N ., Ishihara T. et al. Variability of breath-by-breath tidal volume and its characteristics in normal and diseased subjects. Ventilatory monitoring with electrical impedance pneumography. Jpn. J. Med. 1985; 24 (2): 141-149.

7. Morel D.R., Forster A., Suter P.M. Noninvasive ventilatory monitoring with bellows pneumographs in supine subjects. J. Appl. Physiol. 1983; 55 (2): 598-606.

8. Perez W., Tobin M.J. Separation of factors responsible for change in breathing pattern induced by instrumentation. Ibid. 1985; 59 (5): 1515-1520.

9. Tobin M.J., Chadha T.S., Jenouri G. et al. Breathing patterns. 1. Normal subjects. Chest 1983; 84 (2): 202-205.

10. Tobin M.J., Chadha T.S., Jenouri G. et al. Breathing patterns. 2. Diseased subjects. Ibid. (3): 286-294.


Review

For citations:


Zoulkarneev R.Kh., Zagidullin Sh.Z., Kolikova S.A., Kajumova L.M. Noninvasive breathing pattern monitoring in patients with bronchial asthma. PULMONOLOGIYA. 2003;(3):89-92. (In Russ.)

Views: 298


ISSN 0869-0189 (Print)
ISSN 2541-9617 (Online)