Ecological hygienical expertise of the efficiency of room air environment optimisation with the recirculative unit “Potok-150M”
Abstract
This work is dedicated to the study of the application possibility of the recirculative unit “Potok 150M” (it works according to the principal of the combined electrostatic and mechanical filter) for optimisation of air environment (AE) in the interior premises. With the unit operating under experimental and natural conditions the quality of AE was estimated according to indexes of concentration of aerosol particles (AP), microbe flora (M F), viruses and fungous flora (FF) in air and biologically active gaseous substances (BAYS). The unit ensured the effective drop of AP, MF, FF, styrolene, butylacetate, heptane, O-xylene, benzole, I-m ethy-3-ethylbenzole, 2-methylheptane and other BAYS in AE. The moderate enrichment of AE with light air ions and ozone was also registered. Time of unit operation unit was determined by concrete conditions of micro climate and architecture of premises. Thus, the recirculative unit “Potok 150M” allows to attach qualities to AE according to claimed demands of modern healthy dwelling and hospital premises.
About the Authors
S. O. AleynikovRussian Federation
A. V. Nagolkin
Russian Federation
A. G. Malisheva
Russian Federation
I. E. Furman
Russian Federation
Yu. A. Smirnov
Russian Federation
Yu. G. Suchkov
Russian Federation
V. V. Petrosov
Russian Federation
Z. K. Petrova
Russian Federation
I. I. Vodorackaya
Russian Federation
References
1. Васильева И.И., Чучалин А.Г. Новые аспекты лечения атопической бронхиальной астмы с помощью воздухоочистительного аппарата “АЭР-О-МЕД 150" / / Пульмонология.— 1994.— № 1.— С.65—68.
2. Дорошина Ю .А., Басманов М .М ., Губанкова С.Г. и др. Безаллергенные палаты в лечении поллинозов и бронхиальной астмы / / Тер. арх.— 1986.— № 4.— С.49—51.
3. Луценко М.Г., Целуйко С.С., М анаков Л.Г. и др. Механизмы влияния атмосферных загрязнений на течение заболеваний легких / / Пульмонология.— 1992.— № 1.— С.6— 10.
4. Хаякава И. Чистые помещения.— М.: Мир, 1990.
5. Ackermann R., Behrends Н.В., Ehrensberger R. (Hrsg.). Umwelt und Allergie.— Cloppenburg: G.Runge, 1992.— S. 180.
6. Chai H., Spector S.L. Aerosol and air filter therapy / / Bull. N.Y. Acad. Med.— 1981.— Vol.57.— P.568—571.
7. Durgemann H. Karenz — Expositionsprophylaxe / / Atemwegs — u. Lungenkr.— 1978,— Bd 4, № 7.— S. 10— 15.
8. Edling C., Hellguist H., Odkvist L. Occupational formaldehyd exposure and the nasal mucosa / / Rhinology.— 1987.— Vol.25, № 181.— P.86—88.
9. Jorde W., Schata M. Zur Wirksamkeit von Luftreinigunsgeraten bei Krankheiten mit inhalativer Allergeninvasion / / Atemwegs-u. Lungenkr.— 1988.— Bd 14, № 10.— S.492—497.
10. Jorde W., Schata M. Jnnenraumallergene.— München: Dustri, 1992.— S .182.
11. Lauter H., Schata M. Allergisches Astma bronchiale / / Z . Allgemeinmed.— 1993.— Bd 69, № 7. — S.5.
12. Lippman M. Health effects of ozone. A Critical review / / J. Air Pollut. Control Ass.— 1988.— Vol.39, № 5.— P.672—695.
Review
For citations:
Aleynikov S.O., Nagolkin A.V., Malisheva A.G., Furman I.E., Smirnov Yu.A., Suchkov Yu.G., Petrosov V.V., Petrova Z.K., Vodorackaya I.I. Ecological hygienical expertise of the efficiency of room air environment optimisation with the recirculative unit “Potok-150M”. PULMONOLOGIYA. 1995;(1):64-69. (In Russ.)