Preview

PULMONOLOGIYA

Advanced search

Ecological hygienical expertise of the efficiency of room air environment optimisation with the recirculative unit “Potok-150M”

Abstract

This work is dedicated to the study of the application possibility of the recirculative unit “Potok 150M” (it works according to the principal of the combined electrostatic and mechanical filter) for optimisation of air environment (AE) in the interior premises. With the unit operating under experimental and natural conditions the quality of AE was estimated according to indexes of concentration of aerosol particles (AP), microbe flora (M F), viruses and fungous flora (FF) in air and biologically active gaseous substances (BAYS). The unit ensured the effective drop of AP, MF, FF, styrolene, butylacetate, heptane, O-xylene, benzole, I-m ethy-3-ethylbenzole, 2-methylheptane and other BAYS in AE. The moderate enrichment of AE with light air ions and ozone was also registered. Time of unit operation unit was determined by concrete conditions of micro climate and architecture of premises. Thus, the recirculative unit “Potok 150M” allows to attach qualities to AE according to claimed demands of modern healthy dwelling and hospital premises.

About the Authors

S. O. Aleynikov
НИИ пульмонологии М3 РФ
Russian Federation


A. V. Nagolkin
НИИ экологии человека и гигиены окружающей среды им. А.Н.Сысина РАМН
Russian Federation


A. G. Malisheva
НИИ вирусологии им. Д.И.Ивановского РАМН
Russian Federation


I. E. Furman
НИИ эпидемиологии им. Н.Ф.Гамалеи РАМН
Russian Federation


Yu. A. Smirnov
НПФ “Поток Лтд”
Russian Federation


Yu. G. Suchkov
Городская клиническая больница № 57
Russian Federation


V. V. Petrosov
Городская клиническая больница № 57
Russian Federation


Z. K. Petrova
Городская клиническая больница № 57
Russian Federation


I. I. Vodorackaya
Городская клиническая больница № 57
Russian Federation


References

1. Васильева И.И., Чучалин А.Г. Новые аспекты лечения атопической бронхиальной астмы с помощью воздухоочистительного аппарата “АЭР-О-МЕД 150" / / Пульмонология.— 1994.— № 1.— С.65—68.

2. Дорошина Ю .А., Басманов М .М ., Губанкова С.Г. и др. Безаллергенные палаты в лечении поллинозов и бронхиальной астмы / / Тер. арх.— 1986.— № 4.— С.49—51.

3. Луценко М.Г., Целуйко С.С., М анаков Л.Г. и др. Механизмы влияния атмосферных загрязнений на течение заболеваний легких / / Пульмонология.— 1992.— № 1.— С.6— 10.

4. Хаякава И. Чистые помещения.— М.: Мир, 1990.

5. Ackermann R., Behrends Н.В., Ehrensberger R. (Hrsg.). Umwelt und Allergie.— Cloppenburg: G.Runge, 1992.— S. 180.

6. Chai H., Spector S.L. Aerosol and air filter therapy / / Bull. N.Y. Acad. Med.— 1981.— Vol.57.— P.568—571.

7. Durgemann H. Karenz — Expositionsprophylaxe / / Atemwegs — u. Lungenkr.— 1978,— Bd 4, № 7.— S. 10— 15.

8. Edling C., Hellguist H., Odkvist L. Occupational formaldehyd exposure and the nasal mucosa / / Rhinology.— 1987.— Vol.25, № 181.— P.86—88.

9. Jorde W., Schata M. Zur Wirksamkeit von Luftreinigunsgeraten bei Krankheiten mit inhalativer Allergeninvasion / / Atemwegs-u. Lungenkr.— 1988.— Bd 14, № 10.— S.492—497.

10. Jorde W., Schata M. Jnnenraumallergene.— München: Dustri, 1992.— S .182.

11. Lauter H., Schata M. Allergisches Astma bronchiale / / Z . Allgemeinmed.— 1993.— Bd 69, № 7. — S.5.

12. Lippman M. Health effects of ozone. A Critical review / / J. Air Pollut. Control Ass.— 1988.— Vol.39, № 5.— P.672—695.


Review

For citations:


Aleynikov S.O., Nagolkin A.V., Malisheva A.G., Furman I.E., Smirnov Yu.A., Suchkov Yu.G., Petrosov V.V., Petrova Z.K., Vodorackaya I.I. Ecological hygienical expertise of the efficiency of room air environment optimisation with the recirculative unit “Potok-150M”. PULMONOLOGIYA. 1995;(1):64-69. (In Russ.)

Views: 96


ISSN 0869-0189 (Print)
ISSN 2541-9617 (Online)