The monoclonal anti-IgE-plasmoimmunosorbtion in treatment of atopic bronchial asthma patients
Abstract
Wc have studied the efficacy of monoclonal extracorporeal anti-IgE-plasmoimmunosoibtion (EPIA) in treatment of 16 atopic asthma patients. We used new immunosorbent with immobilized anti-IgE-antibodies. The first group (9 patients) was treated by EPIA, the second group (7 patients) was treated only by placebo procedures. The investigation was done by double blind method. After EPIA in first the group good clinical results were obtained in 8 patients, in the second group we have seen clinical improvement only for a short time. It was not possible to decrease the number o f broncholitics and corticosteroids in patients of the second group. We have seen specific changes of the IgE serum levels after EPIA, but not after placebo procedures. Thus, EPIA is effective extracorporeal method for treatment of atopic asthma patients with high serum levels of IgE and plural hypersensitivity.
About the Authors
A. R. TatarskyRussian Federation
Y. S. Lebedin
Russian Federation
E. V. Bobkov
Russian Federation
A. S. Emirova
Russian Federation
A. G. Chuchalin
Russian Federation
References
1. Адо А.Д. Общая аллергология: Руководство для врачей. 2-е изд.— М.: Медицина, 1978.
2. Бронхиальная астма: принципы диагностики и лечения / Под ред. М.Э.Гершвина: Пер. с англ.— М., 1984.
3. Воробьев А.И., Городецкий В.М., Бриллиант М.Д. Плазмаферез в клинической практике / / Тер. арх.— 1984.— No 6.— С.З—9.
4. Кормош Т. Специфическая иммуносорбция у больных бронхиальной астмой с гиперчувствительностью к аллергену пыльцы тимофеевки: Автореф. дис. ... канд. мед. наук.— М., 1987.
5. Мавраев Д.Э., Казанбиев Д.Н. Экстракорпоральная иммуносорбция: перспективы клинического применения / / Тер. арх.— 1984.— No Ю.— С.65—71.
6. Раудла Л.A . Применение экстракорпоральной специфической иммуносорбции при лечении атопической бронхиальной астмы / / Актуальные вопросы анестезиологии и реаниматологии.— Таллин, 1986.— С.150—152.
7. ЧучалинА.Г. Актуальные вопросы современной пульмонологии / / Тер. арх.— 1986.— No 6.— С.15—20.
8. Чучалин А.Г., Казанбиев Д.Н., Мавраев Д.Э. Экстракорпоральная иммуносорбция при лечении поллиноза / / Клин. мед.— 1987.— No 2.— С.58—61.
9. Burrows В. Association of asthma with serum IgE levels and skin-test reactivity to allergens / / N. Engl. J. Med.— 1989.— Vol.320, No 5.— P.271—277.
10. Charlton B., Schindhelm K. The effect of extracorporeal antibody removal on antibody synthesis and catabolism in immunized rabbits / / Clin. Exp. Immunol.— 1985.— Vol.60, No 3.— P.457—464.
11. Gershwin M.E. Bronchial Asthma.— London: Grune and Stratton 1986.
12. Palmer A., Taube D., Welsh K. Extracorporeal immunoadsorption of anti-HLA antibodies — preliminary clinical experience / / Transplant. Proc.— 1987.— Vol.19, No 5.— P.3750.
13. Pineda A. Selective removal of plasma constituents / / Trans. Am. Soc. Artif. Intern. Organs.— 1984.— Vol.30.— P.671—672.
Review
For citations:
Tatarsky A.R., Lebedin Y.S., Bobkov E.V., Emirova A.S., Chuchalin A.G. The monoclonal anti-IgE-plasmoimmunosorbtion in treatment of atopic bronchial asthma patients. PULMONOLOGIYA. 1994;(2):63-66. (In Russ.)