<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">pulmo</journal-id><journal-title-group><journal-title xml:lang="ru">Пульмонология</journal-title><trans-title-group xml:lang="en"><trans-title>PULMONOLOGIYA</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-0189</issn><issn pub-type="epub">2541-9617</issn><publisher><publisher-name>Scientific and Practical Journal “PULMONOLOGIYA” LLC</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">pulmo-3193</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>REVIEW</subject></subj-group></article-categories><title-group><article-title>Системы ингаляционной доставки препаратов в дыхательные пути</article-title><trans-title-group xml:lang="en"><trans-title>Systems for drugs delivery to airways by inhalation</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Огородова</surname><given-names>Л. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Ogorodova</surname><given-names>L. M.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Сибирский государственный медицинский университет</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>1999</year></pub-date><pub-date pub-type="epub"><day>30</day><month>03</month><year>1999</year></pub-date><volume>0</volume><issue>1</issue><fpage>84</fpage><lpage>87</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Огородова Л.М., 1999</copyright-statement><copyright-year>1999</copyright-year><copyright-holder xml:lang="ru">Огородова Л.М.</copyright-holder><copyright-holder xml:lang="en">Ogorodova L.M.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://journal.pulmonology.ru/pulm/article/view/3193">https://journal.pulmonology.ru/pulm/article/view/3193</self-uri><abstract><p>.</p></abstract></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Бронхиальная астма. Глобальная стратегия. Совместный доклад Национального института Сердце, Легкие, Кровь СШ А и ВОЗ / / Пульмонология.— 1996.— Приложение.— С.1 — 154.</mixed-citation><mixed-citation xml:lang="en">Бронхиальная астма. Глобальная стратегия. Совместный доклад Национального института Сердце, Легкие, Кровь СШ А и ВОЗ / / Пульмонология.— 1996.— Приложение.— С.1 — 154.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Цой А.Н. Преимущества и недостатки приспособлений для индивидуальной ингаляционной терапии / / Пульмонология.— 1997.— № 4.— С.71—74.</mixed-citation><mixed-citation xml:lang="en">Цой А.Н. Преимущества и недостатки приспособлений для индивидуальной ингаляционной терапии / / Пульмонология.— 1997.— № 4.— С.71—74.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Armitage J.M., Williams S.J. Inhaler Technique in the elderly / / Age and ageing.— 1988.— Vol.17.— P.275—278.</mixed-citation><mixed-citation xml:lang="en">Armitage J.M., Williams S.J. Inhaler Technique in the elderly / / Age and ageing.— 1988.— Vol.17.— P.275—278.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Barry P.W., Ocallaghan C. Multiple actuations of salbutamol M DI into a spacer device reduce the amount of drug recovered in the respirable range / / Eur. Respir. J.— 1994.— Vol.7.— P. 1707—1709.</mixed-citation><mixed-citation xml:lang="en">Barry P.W., Ocallaghan C. Multiple actuations of salbutamol M DI into a spacer device reduce the amount of drug recovered in the respirable range / / Eur. Respir. J.— 1994.— Vol.7.— P. 1707—1709.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Brindley A., Sumby B.S., Smith I. et al. Design, manufacture and dose conistency of the Serèvent diskus inhaler / / Pharm. Techn. Eur.— 1995.- Vol.7.— P.14—22.</mixed-citation><mixed-citation xml:lang="en">Brindley A., Sumby B.S., Smith I. et al. Design, manufacture and dose conistency of the Serèvent diskus inhaler / / Pharm. Techn. Eur.— 1995.- Vol.7.— P.14—22.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">British Thoracis Society (BTS) and others. Guadlines on the management of asthma / / Thorax.— 1993.— Vol.48.— Suppl.— P. 1—24.</mixed-citation><mixed-citation xml:lang="en">British Thoracis Society (BTS) and others. Guadlines on the management of asthma / / Thorax.— 1993.— Vol.48.— Suppl.— P. 1—24.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Chou K.J., Cunningham S.J., Crain E.F. Metered-dose inhalers with spacers vs nebulizers for pediatric asthma / / Arch. Pediatr. Adolese.— 1995.— Vol.149.— P.201—205.</mixed-citation><mixed-citation xml:lang="en">Chou K.J., Cunningham S.J., Crain E.F. Metered-dose inhalers with spacers vs nebulizers for pediatric asthma / / Arch. Pediatr. Adolese.— 1995.— Vol.149.— P.201—205.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Crompton G.K. Problems patients have using pressurized aerosol inhalers / / Eur. J. Respir. Dis. Suppl.— 1992.— Vol.119.— P.101 — 104.</mixed-citation><mixed-citation xml:lang="en">Crompton G.K. Problems patients have using pressurized aerosol inhalers / / Eur. J. Respir. Dis. Suppl.— 1992.— Vol.119.— P.101 — 104.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Crompton G.K. Clinical use of dry powder systems / / Eur. J. Respir. Dis. Suppl.— 1992.— Vol.122.— P.96—99.</mixed-citation><mixed-citation xml:lang="en">Crompton G.K. Clinical use of dry powder systems / / Eur. J. Respir. Dis. Suppl.— 1992.— Vol.122.— P.96—99.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Fergusson R.J., Lenney J., Me Hardy G.J.R. et al. The use of a new breath-actuated inhaler by patients with severe airflow obstruction / / Eur. Respir. J.— 1991.— Vol.4.— P. 172—174.</mixed-citation><mixed-citation xml:lang="en">Fergusson R.J., Lenney J., Me Hardy G.J.R. et al. The use of a new breath-actuated inhaler by patients with severe airflow obstruction / / Eur. Respir. J.— 1991.— Vol.4.— P. 172—174.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Gorman P.L., Dawson K.P., Modridge N. Dry powder inhalation devices: consumer perceptious of two new devices / / N.Z.Fam. Phisician.— 1990.— Vol.41.— P.182—183.</mixed-citation><mixed-citation xml:lang="en">Gorman P.L., Dawson K.P., Modridge N. Dry powder inhalation devices: consumer perceptious of two new devices / / N.Z.Fam. Phisician.— 1990.— Vol.41.— P.182—183.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Hardy J., Jasuja A., Perkins A. A small volume spacer for use with a breath-operated pressurised metered dose inhaler / / International. J. of Pharmaceutics.— 1996.— Vol. 142.— P. 129—133.</mixed-citation><mixed-citation xml:lang="en">Hardy J., Jasuja A., Perkins A. A small volume spacer for use with a breath-operated pressurised metered dose inhaler / / International. J. of Pharmaceutics.— 1996.— Vol. 142.— P. 129—133.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Hurrell F. Choosing inhalers devisee for children with asthma / / Paediatr. Nurs.— 1993.— Vol.5.— P.22—24.</mixed-citation><mixed-citation xml:lang="en">Hurrell F. Choosing inhalers devisee for children with asthma / / Paediatr. Nurs.— 1993.— Vol.5.— P.22—24.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Jackson C., Lipworth B. Optimizing inhaled drug delivery in patients with asthma / / Br. J. Gen. Pract.— 1995.— Vol.45.— P.683—687.</mixed-citation><mixed-citation xml:lang="en">Jackson C., Lipworth B. Optimizing inhaled drug delivery in patients with asthma / / Br. J. Gen. Pract.— 1995.— Vol.45.— P.683—687.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Larsen J.S., Hahn M., Ekholm B. et al. Evaluation of conventional press-and-breathe metered-dose inhaler technique in 501 patients. / / J. Asthma.— 1994.— Vol.31.— P.193—199.</mixed-citation><mixed-citation xml:lang="en">Larsen J.S., Hahn M., Ekholm B. et al. Evaluation of conventional press-and-breathe metered-dose inhaler technique in 501 patients. / / J. Asthma.— 1994.— Vol.31.— P.193—199.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Malton A., Pharm B., Sumby B.S., Smiths I.J. A comparison of in vitro drug delivery from two multidose powder inhalation devices / / Eur. Clin. Res.— 1995.— Vol.7.— P.177—193.</mixed-citation><mixed-citation xml:lang="en">Malton A., Pharm B., Sumby B.S., Smiths I.J. A comparison of in vitro drug delivery from two multidose powder inhalation devices / / Eur. Clin. Res.— 1995.— Vol.7.— P.177—193.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Newman S.P., Weisz A.W.B., Talaee N., Clarke S.W. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique / / Thorax.— 1991.— Vol.46.— P.712-716.</mixed-citation><mixed-citation xml:lang="en">Newman S.P., Weisz A.W.B., Talaee N., Clarke S.W. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique / / Thorax.— 1991.— Vol.46.— P.712-716.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Pauwels R., Newman S., Borgstrum L. Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers / / Eur. Resp. J.— 1997.— Vol.10.— P.2127—2138.</mixed-citation><mixed-citation xml:lang="en">Pauwels R., Newman S., Borgstrum L. Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers / / Eur. Resp. J.— 1997.— Vol.10.— P.2127—2138.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Sparma R. K., Edwards K., Hallet C., Fuller R.W. Perception among paediatric of the Diskus inhaler, a novel multidose powder inhaler for use in the treatment of asthma: comparison with the Turbuhaler inhaler / / Clin. Drug. Invest.— 1996.— Vol.11.— P.145—153.</mixed-citation><mixed-citation xml:lang="en">Sparma R. K., Edwards K., Hallet C., Fuller R.W. Perception among paediatric of the Diskus inhaler, a novel multidose powder inhaler for use in the treatment of asthma: comparison with the Turbuhaler inhaler / / Clin. Drug. Invest.— 1996.— Vol.11.— P.145—153.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Woodcock A. Continuing patient care with metered-dose inhalers / / J. Aerosol. Med.— 1995.— Vol.8.— P.5—10.</mixed-citation><mixed-citation xml:lang="en">Woodcock A. Continuing patient care with metered-dose inhalers / / J. Aerosol. Med.— 1995.— Vol.8.— P.5—10.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
