<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">pulmo</journal-id><journal-title-group><journal-title xml:lang="ru">Пульмонология</journal-title><trans-title-group xml:lang="en"><trans-title>PULMONOLOGIYA</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-0189</issn><issn pub-type="epub">2541-9617</issn><publisher><publisher-name>Scientific and Practical Journal “PULMONOLOGIYA” LLC</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">pulmo-2496</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>REVIEW</subject></subj-group></article-categories><title-group><article-title>Эффективность и безопасность ультрамелкодисперсного беклометазона дипропионата у больных бронхиальной астмой (Обзор литературы)</article-title><trans-title-group xml:lang="en"><trans-title>Efficacy and safety of ultra-fine dispersed beclomethasone dipropionate in bronchial asthma patients (review)</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Емельянов</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Emelyanov</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Санкт-Петербург.</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Санкт-Петербургский государственный Медицинский университет им. акад. И.П.Павлова</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2004</year></pub-date><pub-date pub-type="epub"><day>17</day><month>08</month><year>2021</year></pub-date><volume>0</volume><issue>5</issue><fpage>108</fpage><lpage>112</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Емельянов А.В., 2021</copyright-statement><copyright-year>2021</copyright-year><copyright-holder xml:lang="ru">Емельянов А.В.</copyright-holder><copyright-holder xml:lang="en">Emelyanov A.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://journal.pulmonology.ru/pulm/article/view/2496">https://journal.pulmonology.ru/pulm/article/view/2496</self-uri><abstract><p>.</p></abstract><kwd-group xml:lang="ru"><kwd>бронхиальная астма</kwd></kwd-group><kwd-group xml:lang="en"><kwd>bronchial asthma</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Global initiative for asthma. — NHLB/WHO Workshop report. — National Heart Lung Blood Institute, Publication number 02-3659, 2002.</mixed-citation><mixed-citation xml:lang="en">Global initiative for asthma. — NHLB/WHO Workshop report. — National Heart Lung Blood Institute, Publication number 02-3659, 2002.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Barnes P.J., Pedersen S., Busse W.W. Efficacy and safety of inhaled corticosteroids. New development. Am. J. Respir. Crit. Care Med. 1998; 157 (3, pt 2): 1S-53S.</mixed-citation><mixed-citation xml:lang="en">Barnes P.J., Pedersen S., Busse W.W. Efficacy and safety of inhaled corticosteroids. New development. Am. J. Respir. Crit. Care Med. 1998; 157 (3, pt 2): 1S-53S.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Suissa S., Ernst P. Inhaled corticosteroids: impact on asthma morbidity and mortality. J. Allergy Clin. Immunol. 2001; 107 (6): 937-944.</mixed-citation><mixed-citation xml:lang="en">Suissa S., Ernst P. Inhaled corticosteroids: impact on asthma morbidity and mortality. J. Allergy Clin. Immunol. 2001; 107 (6): 937-944.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Suissa S., Ernst P., Benayoun S. et al. Low-dose of inhaled corticosteroids and prevention of death from asthma. N. Engl. J. Med. 2000; 343 (5): 332-336.</mixed-citation><mixed-citation xml:lang="en">Suissa S., Ernst P., Benayoun S. et al. Low-dose of inhaled corticosteroids and prevention of death from asthma. N. Engl. J. Med. 2000; 343 (5): 332-336.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Leach C.L. Improved delivery of inhaled steroids to the large and small airways. Respir. Med. 1998; 92 (suppl. A): 3-8.</mixed-citation><mixed-citation xml:lang="en">Leach C.L. Improved delivery of inhaled steroids to the large and small airways. Respir. Med. 1998; 92 (suppl. A): 3-8.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Goodman D., Israel E., Rosenberg M. et al. The influence of age, diagnosis and gender on proper use of metered dose inhalers. Am. J. Respir. Crit. Care Med. 1994; 150: 1256-1261.</mixed-citation><mixed-citation xml:lang="en">Goodman D., Israel E., Rosenberg M. et al. The influence of age, diagnosis and gender on proper use of metered dose inhalers. Am. J. Respir. Crit. Care Med. 1994; 150: 1256-1261.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Kamps A.W., van Ewjil B., Roorda R.J. et al. Poor inhalation technique even after inhalation instructions, in children with asthma. Pediatr. Pulmonol. 2000; 29 (1): 39-42.</mixed-citation><mixed-citation xml:lang="en">Kamps A.W., van Ewjil B., Roorda R.J. et al. Poor inhalation technique even after inhalation instructions, in children with asthma. Pediatr. Pulmonol. 2000; 29 (1): 39-42.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Shresthna M., Parupia H., Andrews B. et al. Metered dose inhaler technique of patients in urban ED: prevalence of incorrect technique and attempt at education. Am. J. Emerg. Med. 1996; 14 (4): 380-384.</mixed-citation><mixed-citation xml:lang="en">Shresthna M., Parupia H., Andrews B. et al. Metered dose inhaler technique of patients in urban ED: prevalence of incorrect technique and attempt at education. Am. J. Emerg. Med. 1996; 14 (4): 380-384.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Davies R.J., Stampone P., O'Conner B.J. Hydrofluoroalkane-134a beclomethasone dipropionate extrafine aerosol provides equivalent asthma control to chlorofluorocarbone beclomethasone dipropionate at approximately half the total dose. Respir. Med. 1998; 92 (suppl. A): 23-31.</mixed-citation><mixed-citation xml:lang="en">Davies R.J., Stampone P., O'Conner B.J. Hydrofluoroalkane-134a beclomethasone dipropionate extrafine aerosol provides equivalent asthma control to chlorofluorocarbone beclomethasone dipropionate at approximately half the total dose. Respir. Med. 1998; 92 (suppl. A): 23-31.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Gross G., Thompson P.J., Chervinsky P. et al. Hydrofluoro-alkane-134a Beclomethasone Dipropionate, 400 mg, is as effective as chlorofluorocarbon Beclomethasone Dipropionate, 800 mg, for the treatment of moderate asthma. Chest 1999; 115 (2): 343-351.</mixed-citation><mixed-citation xml:lang="en">Gross G., Thompson P.J., Chervinsky P. et al. Hydrofluoro-alkane-134a Beclomethasone Dipropionate, 400 mg, is as effective as chlorofluorocarbon Beclomethasone Dipropionate, 800 mg, for the treatment of moderate asthma. Chest 1999; 115 (2): 343-351.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Busse W., Brazinsky S., Jacobson K. et al. Efficacy response of inhaled beclomethasone dipropionate in asthma is proportional to dose and is improved by formulation with a new propelent. J. Allergy Clin. Immunol. 1999; 104 (6): 1215-1222.</mixed-citation><mixed-citation xml:lang="en">Busse W., Brazinsky S., Jacobson K. et al. Efficacy response of inhaled beclomethasone dipropionate in asthma is proportional to dose and is improved by formulation with a new propelent. J. Allergy Clin. Immunol. 1999; 104 (6): 1215-1222.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Firemann P, Prenner B.M., Vinsken W. et al. Long term safety and efficacy of chlorofluorocarbon-free beclomethasone dipropionate extrafine aerosol. Ann. Allergy Asthma Clin. Immunol. 2001; 86 (5): 557-565.</mixed-citation><mixed-citation xml:lang="en">Firemann P, Prenner B.M., Vinsken W. et al. Long term safety and efficacy of chlorofluorocarbon-free beclomethasone dipropionate extrafine aerosol. Ann. Allergy Asthma Clin. Immunol. 2001; 86 (5): 557-565.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Magnussen H. E quivalent asthma control after dose reduction with HFA 134a beclomethasone solution aerosol. Comparative Inhaled Steroid Investigation Group (CISIG). Respir. Med. 2000. 94: 561-567.</mixed-citation><mixed-citation xml:lang="en">Magnussen H. E quivalent asthma control after dose reduction with HFA 134a beclomethasone solution aerosol. Comparative Inhaled Steroid Investigation Group (CISIG). Respir. Med. 2000. 94: 561-567.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Juniper E., Price D., Stampone P.A. et al. Clinically important improvement in asthma-specific quality of life, but no difference in conventional clinical indexes in patients changed from conventional beclomethasone dipropionate tp approximately half the dose of extrafine beclomethasone dipropionate. Chest 2002; 121 (6): 1824-1832.</mixed-citation><mixed-citation xml:lang="en">Juniper E., Price D., Stampone P.A. et al. Clinically important improvement in asthma-specific quality of life, but no difference in conventional clinical indexes in patients changed from conventional beclomethasone dipropionate tp approximately half the dose of extrafine beclomethasone dipropionate. Chest 2002; 121 (6): 1824-1832.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Aubier M., Wettenger R., Gans S.J. Efficacy of HFA-beclametha-sone dipropionate extra-fine aerosol (800 md/day) versus HFA-fluticasone propionate (1000 md/day) in patients with asthma. Respir. Med. 2001; 95 (1): 212-220.</mixed-citation><mixed-citation xml:lang="en">Aubier M., Wettenger R., Gans S.J. Efficacy of HFA-beclametha-sone dipropionate extra-fine aerosol (800 md/day) versus HFA-fluticasone propionate (1000 md/day) in patients with asthma. Respir. Med. 2001; 95 (1): 212-220.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Worth H., Muir J.F., Pieters W.R. Comparison of Hydro-fluoroalkane-Beclomethasone Dipropionate AutohalerTM with Budesonide Turbuhaler TM in asthma control. Respiration 2001; 68: 517-526.</mixed-citation><mixed-citation xml:lang="en">Worth H., Muir J.F., Pieters W.R. Comparison of Hydro-fluoroalkane-Beclomethasone Dipropionate AutohalerTM with Budesonide Turbuhaler TM in asthma control. Respiration 2001; 68: 517-526.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Thompson P., Davies R.J., Yong W.F. et al. Safety of hydroflu-oroalkane-134 a beclomethasone propionate extrafine aerosol. Respir. Med. 1998; 92 (suppl.A): 33-39.</mixed-citation><mixed-citation xml:lang="en">Thompson P., Davies R.J., Yong W.F. et al. Safety of hydroflu-oroalkane-134 a beclomethasone propionate extrafine aerosol. Respir. Med. 1998; 92 (suppl.A): 33-39.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Reichel W.t Dahl R., Ringdal N. et al. Extrafine beclometasone dipropionate breath actuated inhaler (400 mcg/day) versus budesonide dry power inhaler (800 mcg/day) in asthma. Int. J. Clin. Pract. 2001; 55 (1): 100-106.</mixed-citation><mixed-citation xml:lang="en">Reichel W.t Dahl R., Ringdal N. et al. Extrafine beclometasone dipropionate breath actuated inhaler (400 mcg/day) versus budesonide dry power inhaler (800 mcg/day) in asthma. Int. J. Clin. Pract. 2001; 55 (1): 100-106.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Rocca-Serra J.P., Vicaut E, Lefrancois G, Umile A. Efficacy and tolerability of new non-extrafine formulation of beclomethasone HFA-134a in patients with asthma. Comparison with Beclomethasone CFC. Clin. Drug Invest. 2002; 22 (10): 653-665.</mixed-citation><mixed-citation xml:lang="en">Rocca-Serra J.P., Vicaut E, Lefrancois G, Umile A. Efficacy and tolerability of new non-extrafine formulation of beclomethasone HFA-134a in patients with asthma. Comparison with Beclomethasone CFC. Clin. Drug Invest. 2002; 22 (10): 653-665.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Lenney J., Innes J., Cropmton G.K. Inappropriate inhaler use: assessment of use and preference of seven inhalation devices. Respir. Med. 2000; 94: 496-500.</mixed-citation><mixed-citation xml:lang="en">Lenney J., Innes J., Cropmton G.K. Inappropriate inhaler use: assessment of use and preference of seven inhalation devices. Respir. Med. 2000; 94: 496-500.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Price D., Thomas M., Mitchell G. et al. Improvement of asthma control with breath-actuated pressurized metered dose inhaler (BAI); a prescribing claims study of 5556 patients using a traditional pressurized metered dose inhaler (MDI) or breath-actuated device. Respir. Med. 2003; 97 (1): 12-19.</mixed-citation><mixed-citation xml:lang="en">Price D., Thomas M., Mitchell G. et al. Improvement of asthma control with breath-actuated pressurized metered dose inhaler (BAI); a prescribing claims study of 5556 patients using a traditional pressurized metered dose inhaler (MDI) or breath-actuated device. Respir. Med. 2003; 97 (1): 12-19.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Haycox A., Mitchel G., Nizol C. et al. Cost effectiveness of asthma treatment with breath-actuated pressurized metered dose inhaler (BAI)-a prescribing claim study of 1856 patients using a traditional pressurized metered dose inhaler (MDI) or breath-actuated device. J. Med. Econom. 2002; 5 (1): 65-77.</mixed-citation><mixed-citation xml:lang="en">Haycox A., Mitchel G., Nizol C. et al. Cost effectiveness of asthma treatment with breath-actuated pressurized metered dose inhaler (BAI)-a prescribing claim study of 1856 patients using a traditional pressurized metered dose inhaler (MDI) or breath-actuated device. J. Med. Econom. 2002; 5 (1): 65-77.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Lipworth B.J. Targets for inhaled treatment. Respir. Med. 2000; 94 (suppl. D): S13-S16</mixed-citation><mixed-citation xml:lang="en">Lipworth B.J. Targets for inhaled treatment. Respir. Med. 2000; 94 (suppl. D): S13-S16</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Edbasker S. Pharmacological factors that influence the choice of inhaled corticosteroids. Drugs 1999; 58 (suppl 4): 7-16.</mixed-citation><mixed-citation xml:lang="en">Edbasker S. Pharmacological factors that influence the choice of inhaled corticosteroids. Drugs 1999; 58 (suppl 4): 7-16.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Kelly H.W. Establishing a therapeutic index for the inhaled corticosteroids: Part I. Pharmacokinetic/pharmacodynamic comparison of the inhaled steroids. J. Allergy Clin. Immunol. 1998; 102 (4, pt 2): S36-S5I.</mixed-citation><mixed-citation xml:lang="en">Kelly H.W. Establishing a therapeutic index for the inhaled corticosteroids: Part I. Pharmacokinetic/pharmacodynamic comparison of the inhaled steroids. J. Allergy Clin. Immunol. 1998; 102 (4, pt 2): S36-S5I.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Ganderton D., Lewis D., Davies R. Modulite®: a mean of designing the aerosol generated by pressurized metered dose inhalers. Respir. Med. 2002; 96 (suppl. D): S3-S8.</mixed-citation><mixed-citation xml:lang="en">Ganderton D., Lewis D., Davies R. Modulite®: a mean of designing the aerosol generated by pressurized metered dose inhalers. Respir. Med. 2002; 96 (suppl. D): S3-S8.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
